Description
Overview
GAOTek ultrasonic flow meter is flowmeter can be virtually applied to a wide range of measurement. A variety of liquid applications can be accommodated: ultra-pure liquids, potable water, chemicals, raw sewage, reclaimed water, cooling water, river water, plant effluent.
Features
- Clamp on trandsucers
- Clamp on mounting bracket
- Measuring diagram
Technical Specifications
Principle | Transit time ultrasonic flowmeter |
Accuracy | ± 1 % |
Display | 4 × 16 character LCD with backlight, support the language of Chinese, English and Italy |
Data Interface | Insulate Rs 232 serial interface, upgrade the flowmeter software by computer |
Pipe Diameters | 0 .98 in to 236.22 in (25 to 6000 mm) |
Straight Pipe | Transducer installation should be satisfied: upstream 10 D, downstream 5D, 30 D from the pump |
Type Of Liquid | Single liquid can transmit sound wave,such as Water (hot water, chilled water, city water, sea water, waste water, etc.); Ultra- pure liquids, etc. |
Turbidity | No more than 10000 ppm and less bubble |
Flowrate | 0 ft to 32.80 ft (0 m to ± 10 m) or s |
Temperature | Convertor:  -4 °F to 140 °F ( 20 ℃ to 60 ℃) Flow Transducer: -22 °F to 320 °F (- 30 to 160 ℃) |
Humidity | Convertor: 85% RH;Flow Transducer : |
Dimension | 7.87 in x 3.66 in x 1.25 in (200 mm x 93 mm x 32 mm) |