Description
OverviewÂ
GAOTek Intelligent Residual Chlorine Meter with Platinum Electrodes for Industrial Use is a totally new industrial residual chlorine analyzer, with high intelligence and sensitivity. It can measure residual chlorine and temperature simultaneously. It is widely used in such industries as thermal power plants, running water, pharmaceutical, drinking water, water purification, industrial pure water, swimming pool is infection residual chlorine continuous monitoring. This is an electrode for measuring the constant voltage principal water chlorine, chlorine dioxide, ozone. Constant voltage measurement maintains a stable electric potential at the measurement side of the electrode, different components produce different current intensity at the electric potential when measured. The micro-current measurement system consists of two platinum electrodes and a reference electrode consisting of. Chlorine, chlorine dioxide, ozone will be consumed when water sample flowing through the measuring electrode, therefore, must maintain the water sample continue flow the measuring.Â
Technical Specifications
Measuring range | 0.005 ppm to 20 ppm (mg or L)Â |
Accuracy | ±2% or ±10 ppb |
Electrodes | glass bulb, Platinum |
Certification | CE, ISOÂ |
Body Material | Glass |
keyword 3 | residual chlorine probe |
Cable length | 5 m silver-plated three-core cable |
Working pressure | 10 bars at 68 °F (20℃) |
Dimensions | length 4.3 in (110 mm), 0.4 in (12 mm) diameter |
Reference electrode | gel with annular contacts |
Measuring range | Residual chlorine: 0 mg to 20.00 mg or L, Resolution: 0.01 mg or L; Temperature: 32 °F to 211.8 °F (0 ℃ to 99.9 ℃), Resolution: 32.18 °F (0.1 ℃) |
Accuracy | Chlorine: better than ±1% or ± 0.01 mg or L. |
Temperature | better than ±32.9 °F (0.5 ℃) 32 °F to 122 °F (0 ℃ to 50.0 ℃) |
Minimum detection | 0.01 mg or LÂ |
Repeatability Chlorine | ±0.01 mg or L |
Stability Chlorine | ±0.01 (mg or L) or 24 h |
Current isolated output | 4 mA to 20 mA (load <750 Ω) current output, measurement parameters can be selected independently (FAC, T) |
Output current error |  ≤±1% FS |
High and low alarm | AC 220 V, 5A, each channel can be selected independently measured parameters corresponding (FAC, T) |
Alarm hysteresis | can be set according to the selected parameters |
Communication | RS 485 (optional)Â |
Working environment | Temperature 32°F to 140 °F (0 ℃ to 60 ℃), Relative humidity, convenient to computer monitoring and communication |
Installation type | Opening type, panel mounted |
Dimensions | 3.77 in x 3.77 in x 4.6 mm (96 mm × 96 mm × 118 mm); Hole Size: 3.62 in x 3.62 in (92 mm x 92 mm) |