Description
Overview
This Gloss Meter with Accurate Measurement (Auto Calibration) is designed to measure the gloss of a surface in the range from 0.1 GU to 200 GU with the measuring angle of 60°. The memory can store data upto 254 groups of measurements. Auto calibration, built-in lithium-ion rechargeable battery, USB/RS-232 data output, and backlight display are some of its important features. This easy to carry meter is widely used in surface cleaning quality control, floor maintenance, and stone and tile gloss measurement.The technical parameters complies with JJG696-2002 standards.
Key Features
- In accordance with international standard ASTMD523, ASTMD1455, ASTMC346, ASTMC584, ASTMD2457, DIN ENISO2813, DIN67530, ENISO7668, JISZ8741, MFT30064, TAPPIT480, GB9754, GB/T13891, GB7706 and GB8807. Its technical parameters conform with JJG696-2002.
- Accurate measurement, good repetiti
- Small in size, easy to carry.
- Auto calibration.
- Intelligent design, rapid measurement.
- Able to store 254 groups of measurements.
- Built-in lithium-ion rechargeable battery.
- Backlight display, suitable for the low light environment.
- Use USB/RS-232 data output to connect to PC.
- Provide Bluetooth data output choice.
- Gloss units: GU
Technical Specifications
Display | 4 Digits Backlit LCD |
Measuring Angle | 60º |
Range | 0.1 ~ 200 GU |
Resolution | 0.1 |
Repeatability | ±0.5 GU |
Accuracy | ±1.0 GU |
Data Memorized | 254 Groups |
Measuring Area | 0.27 in x 0.55 in (7 mmx14 mm) (Ellipse) |
Operating Temperature | 32 °F~104 °F (0 ºC~40 ºC) |
Operating Humidity | Humidity: <85% RH |
Power Supply | 4×1.5 V AAA Size (UM-4) Battery |
Dimensions | Main Unit: 6.14 in x 2.63 in x 1.10 in (156 mm x 67 mm x 28 mm) |
Probe: 2.28 in x1.10 in x 4.25 in (58 mm x 28 mm x108 mm) | |
Weight | 0.41 lbs (190 g) (without batteries) |
Additional Information
Standard Accessories
- Main Unit
- Holder with Calibration Standard
- External Probe
- Optical Cleaning Cloth
- Carrying Case
- Operation Manual
Optional Accessories
- Cable & software for RS232C
- USB adapter
- Bluetooth interface.
Applications
Widely used in floor maintenance, surface cleaning quality control, stone and tile gloss measurement, checking printed matter, quality control of paint and ink, polished metal surface, measurement (chrome plating), inspection of paint protection and waxing, auto-body paint inspection, surface inspection of plastic moldings, evaluation of detergents and washers, checking masonry and washers, and checking building exteriors.
Front Panel Descriptions
6-1 Sensor Plug
6-2 Display
6-3 Number memorized
6-4 Measuring key
6-5 Delete key
6-6 Read/Up key
6-7 CAL/Down key
6-8 Power key
6-9 Incident Angle key
6-10 Jack for RS232 interface
6-11 Measurement Aperture
6-12 Protective cap with the calibration standard
6-13 Battery cover/compartment
Power ON / OFF
Press the key to power on the meter. To turn it off, just press this key again. This meter is powered by x AAA dry cell batteries. To install or replace the batteries, just remove the battery cover and insert the new cells in the battery cartridge. Pay attention to the battery pole.
Calibration
Lay the main unit into the holder with calibration standard of high gloss black tile. Take a reading by pressing the “MEAS” key. Compare the measured value with the value marked on the tile. If it matches the value on the tile holder, the instrument is within calibration and standard ready for use. If the measured value does not match the assigned value, just press the CAL key. It is necessary to inspect the condition of the calibration tile and instrument optics before each calibration. Any dust or debris on the optic should be blown from the lenses using dry clean air, the optics must not be touched. If there are any permanent marks or scratches on the lenses, the instrument is no longer suitable for measuring and should be returned to an authorized service center. The calibration tile must be perfectly clean from smears and scratches before attempting calibration. Fingerprints and dust can be removed with the supplied optic cleaning cloth.
Measurement
Remove the holder and lay the Measurement Aperture just against the position that you want to measure. Take a measurement by pressing the “MEAS” key. The reading on the Display Screen within 2 seconds is the gloss value of that position. Meanwhile, the result is stored in memory automatically. When the instrument is placed on a sample the aperture is hidden, the center of the measurement area can be pinpointed by the intersection of the arrows marked on the front of the instrument case with those on the side.
Data Memorizing
When taking measurements, all values will be stored automatically in memory and the number of stored reading is accordingly increased by 1. The gloss meter can store up to 254 groups of data with measurement conditions. If the memory is full, the tester will auto save the new reading and discard the oldest one. That means the tester only holds the last 254 groups of data in memory.
Memory Recall
Under the measuring mode marked by ‘M’ on the display, press the key to enter into the mode of viewing stored values marked by ‘R’. Press key or key to recall stored values forward and backward. To return to the measurement state, just press any key other than or key.
Delete Data in Memory
In the measurement state marked by ‘M’ on the display, the new reading can be deleted by pressing key “DEL”, and the number of stored reading is accordingly decreased by 1. To clear memory, just press and hold “DEL” key for 3 seconds till the number of stored reading becomes 000.
Download to PC
This meter can communicate with a PC by optional USB or RS232C cable and software. All the memorized data can download to your PC every time when in a measurement state marked by “MEAS” when you press key to enter the viewing memorized state.
Auto Power Off
The instrument features an auto power off function designed to conserve battery life. If the tool is idle (neither measuring nor any key operation) for 10 minutes, it will turn itself off.
Battery Replacement
When the battery symbol appears on the display, it is time to replace the batteries. Slide the Battery Cover away from the instrument and remove the batteries. Install batteries paying careful attention to polarity.
Notes:
- The holder removed from the main unit should be kept in a safe and clean place to prevent from damage or pollution.
- While measuring please keep environment light from directly irradiating into the measurement aperture.
- If necessary, especially under strong light, shade it with a piece of light-tight cloth.
- A big temperature difference between environment and meter would badly affect measuring accuracy. In such a case, please wait for a period of time till the temperature get to a balance and then calibrate the meter again.
- If measurement operation lasts a long time, for example, an hour or more, it is necessary to recalibrate the meter.