Description
Overview
GAOTek Gloss Meter with Rapid Measurement (Large Storage) is designed to be used in floor maintenance and surface cleaning quality control with the measuring angle of 20°/60°.It can store 254 groups of measurement data. Its technical parameters conforms to JJG696-2002 and comes with a separate probe for flexible usage. The device also comes with a 4 digits backlit LCD, uses 4 x 1.5 VAAA battery and has a Range of 0.1 to 200 gloss units. The device is widely used in Floor maintenance, Surface cleaning quality control, Stone and tile gloss measurement, Checking printed matter, Quality control of paint and ink, Polished metal surface ,measurement (chrome plating), Inspection of paint, protection and waxing, Auto-body paint inspection, Surface inspection of plastic mouldings, Evaluation of detergents and washers, Checking masonry and washers, Checking building exteriors.
Key Features
- In accordance with international standard ASTM D523, ASTM D1455, ASTM C346, ASTM C584, ASTM D2457, DIN EN ISO 2813 , DIN67530 , EN ISO 7668 , JIS Z 8741, MFT 30064, TAPPI T 480, GB 9754, GB/T13891, GB 7706 and GB 8807.
- Technical parameters conform to JJG696-2002.
- Flexible use with its separate probe
- Accurate measurement, good repetitiveness.
- Small in size, easy to carry.
- Auto calibration.
- Intelligent design, rapid measurement.
- Able to store 254 groups of measurements
- Stores 254 groups of measurements
- Intelligent Design, Ease-in-operation
Technical Specifications
Display | 4 digits backlit LCD |
Measuring geometry | 20°/60° |
Range | 0.1 to 200 gloss units |
Accuracy | ± 1.0 glass units |
Resolution | 0.1 gloss unit |
Repeatability | ±0.5 GU |
Measuring Area | 0.27 in x 0.55 in (7 x 14 mm) ellipse |
Data Memorised | 254 groups |
Data Output | RS 232 C serial Interface |
Power Supply | 4 × 1.5 VAAA battery |
Dimensions (main unit) | 6.15 in x 2.64 in x 1.10 in
(156 mm x 67 mm x 28 mm) |
Separate Sensor | 2.28 in x 1.10 in x 4.25 in
(58 mm x 28 mm x 108 mm) |
Weight | about 0.41 lbs (190 g) ( without batteries ) |
Operating Temperature Range | 32 °F ~ 104 °F (0 ~ 40 °C) |
Humidity | Up to 85 % |
Additional Information
Accessories
- Carrying case – 1 pc
- Operation manual – 1 pc
- External probe – 1 pc
- Holder with calibration standard – 1 pc.
- Optic cleaning cloth – 1 pc.
Optional accessories
- Cable and software for RS232C
- USB adaptor
- Bluetooth interface
Front Panel Descriptions
6-1 Sensor Plug
6-2 Display
6-3 Number Memorized
6-4 Measuring key
6-5 Delete key
6-6 Read/Up key
6-7 CAL/Down key
6-8 Power key
6-9 Incident Angle key
6-10 Jack for RS232 interface
6-11 Measurement Aperture MEAS
6-12 Protective Cap with calibration standard
6-13 Battery cover/compartment
Power ON / OFF
Press the key to power on the meter. To turn it off, just press this key again. This meter is powered with x AAA dry cell batteries. To install or replace the batteries, just remove the battery cover and Insert the new cells in the battery cartridge. Pay attention to the battery pole.
Calibration
Lay the main unit into the holder with calibration standard of high gloss black tile. Take a reading by pressing the “MEAS” key. Compare the measured value with the value marked on the tile. If it matches the value on the tile holder, the instrument is within calibration and ready for use. If the measured value does not match the assigned value, just press the “CAL/▼” key. It is necessary to inspect the condition of the calibration tile and instrument optics before each calibration. Any dust or debris on the optic should be blown from the lenses using dry clean air, the optics must not be touched. If there are any permanent marks or scratches on the lenses, the instrument is no longer suitable for measuring and should be returned to an authorized service centre. The calibration tile must be perfectly clean from smears and scratches before attempting calibration. Finger prints and dust can be removed with the supplied optic cleaning cloth.
Measurement
Remove the holder and lay the Measurement Aperture just against the position that you want to measure. Take a measurement by pressing the “MEAS” key. The reading on the Display Screen within 2 seconds is the gloss value of that position. Meanwhile the result is stored into memory automatically. When the instrument is placed on the sample the aperture is hidden, the centre of the measurement area can be pinpointed by the intersection of the arrows marked on the front of the instrument case with those on the side.
Data Memorizing
When taking measurements, all values will be stored automatically in memory and the number of stored reading is accordingly increased by ‘The gloss meter’ can store up to 254 groups of data with measurement conditions. If the memory is full, the tester will auto save the new reading and discard the oldest one. That means the tester only hold the last 254 groups of data in the memory
Memory Recall
Under the measuring mode marked by ‘M’ on the display, press the “▲/RD” key to enter into mode of viewing stored values marked by ‘R’. Press “▲/RD” key or “CAL/▼” key to recall stored values forward and backwards. To return to the measurement state, just press any key other than “▲/RD” or “CAL/▼” key.
Delete data in memory
In the measurement state marked by ‘M’ on the display , the new reading can be deleted by pressing “DEL” key , and the number of stored reading is accordingly decreased by 1. To clear memory, just press “DEL” and hold key for 3 seconds till the number of stored reading becomes 000.
Download to PC
This meter can communicate with a PC by optional USB or RS232C cable and software. All the memorized data can download to your PC every time when in a measurement state marked by “MEAS” when you press “▲/RD” key to enter the viewing memorized state
Auto Power Off
The instrument features an auto power off function designed to conserve battery life. If the tool is idle (neither measuring nor any key operation) for 10 minutes, it will turn itself off.
Battery Replacement
When the battery symbol appears on the display, it is time to replace the batteries. Slide the Battery Cover away from the instrument and remove the batteries. Install batteries paying careful attention to polarity.
Notes:
- The holder removed from the main unit should be kept in a safe and clean place to prevent from damage or pollution.
- While measuring keep the environment in light from directly irradiating into the measurement aperture. If necessary, especially under strong light, shade it with a piece of light-tight cloth.
- A big temperature difference between environment and meter would badly affect measuring accuracy. In such a case, please wait for a period of time till the temperature get to a balance and then calibrate the meter again.
- If measurement operation lasts a long time, for example an hour or more, it is necessary to recalibrate the meter