Description
Features
- 2 Channel Digital Oscilloscope + Arbitrary or Function
- Waveform Generator + Synchronizing Signal + External Trigger;
- The Keys for oscilloscope and waveform
- generator is separated for convenient to operate it simultaneously;
- Large and clear display 7 in (17.7 cm) 64 K color LCD display,
- Resolution 800 x 480, clearer and more realistic waveform;
- Oscilloscope: 1 GSa or s Sample Rate
- 200 MHz or 100 MHz or 70 MHz Bandwidth,
- more than 20 kinds of auto measurement functions;
- Powerful Trigger Function: Edge, Video, Pulse, Slope, Over time
- Arbitrary or Function Waveform Generator: 25 MHz, 12 bits resolution,
- 200 MHz DDS, Arbitrary wave or square wave or sine wave or triangle
- Wave or trapezoidal wave or pulse wave
- DC is easy to simulate transducer.
- Support SD card, VGA function (optional);
- Integrated USB Host, Support USB disk storage
- USB interface or SD card system update.
Technical Specification
Sample Rate | Range: 1 GSa/s Equivalent Sample Rate: 25 GSa/s |
Normal | Normal data only |
Peak Detect | High-frequency and Random glitch capture |
Average | Waveform Average, selectable 4, 8, 16, 32, 64, 128 |
Inputs Coupling | AC, DC, GND |
Inpits Impendence | 1 MΩ ±2% 20 pF ±3 pF |
Probe Attenuation | 1 X, 10 X |
Supported Probe Attenuation Factor | 1 X, 10 X, 100 X, 1000 X |
Maximum Input Voltage | CAT I and CAT II: 300 VRMS (10 ×)CAT III: 150 VRMS (1 ×);
Installation Category II: derate at 20 dB or decade above 100 kHz to 13 V peak AC at 3 MHz × and above. For non-sinusoidal waveforms, peak value must be less than 450 V. Excursion above 300 V should be of less than 100 ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300 V. If these values are exceeded, damage to the oscilloscope may occur. |
Sample Rate Range | 1 GS/s |
Waveform Interpolation | (sin x) / x |
Record Length | 40 K |
SEC or DIV Range | 2 ns/div to 40 s/div |
Sample Rate and Delay Time Accuracy | ±50 ppm (at over any ≥1 ms time interval) |
Position Range | 2 ns or div to 8 ns or div;(-8 div x s or div) to 20ms;
20 ns or div to 80 us or div; (-8 div x s or div) to 40 ms; 200 us or div to 40 s or div; (-8 div x s or div) to 400 s |
Delta Time Measurement Accuracy (Full Bandwidth) |
Single-shot, Normal mode: ± (1 sample interval +100 ppm × reading + 0.6 ns); >16 averages: ± (1 sample interval + 100 ppm × reading + 0.4 ns); Sample interval = s or div ÷ 200 |
Vertical Resolution | 8-bit resolution, all channel sampled simultaneously |
Position Range | 2 mV or div to 10 V or div |
Bandwidth | 200 MHz, 100 MHz, 70 MHz |
Rise Time At BNC (Typical) | 1.8 ns, 3.5 ns, 5 ns |
Single Gross Weight | 11 lb (5 kg) |