Description
Overview
GAOTek digital spectrophotometer colorimeter is the new model of bench-top spectrophotometer. It is an all-in-one model and can measure both reflectance and transmittance. It can measure both opaque and transparent materials such as paint, textile, plastic, master batches, printing materials, glasses, liquid and powder materials, etc.
Features
- Instrument adopts xenon lamp
- It can measure both reflectance and transmittance
- Auto temperature and humidity compensation function
- 4 kinds of UV modes for choices
- 4 test apertures as standard accessories, auto aperture size recognition
- 10 million samples storage memory
- Instrument is with camera to view the measurement area
- Vertical and horizontal measurement for testing different kinds of samples
Technical Specifications
Illumination or Viewing System | Reflection, d or 8 (Diffused illumination, 8-degree viewing), Simultaneous measurement of SCI or SCE (CIE No.15, BG or T 3978, GB or T 2893, BG or T 18833, ISO7724 or 1, DIN 5033, ASTM E1164, Teil7, JIS Z8722 Condition C standard) Transmittance d or 0 (Diffused illumination, 0-degree viewing) |
Sphere Diameter | 5.9 in (152 mm) |
Wavelength | 360 nm to 780 nm |
Wavelength Pitch | 10 nm |
Reflectance Range Resolution |
0% to 200%, 0.01% |
Light Source | Pulse Xenon Lamp |
UV Measurement | Include UV, 400 nm cut, 420 nm cut, 460 nm cut |
Measurement Time | SCI or SCE < 2 sec, SCI + SCE < 4 sec |
Measurement Aperture | Reflectance, XLAV 1 in or 1.18 in (Φ 25.4 mm or Φ 30 mm) LAV 0.59 in or 0.70 in (Φ 15 mm or 18 mm), MAV 0.31 in or 0.43 in (Φ 8 mm or Φ 11 mm), SAV 0.11 in or 0.23 in (Φ 3 mm or Φ 6 mm) (Aperture size can be custom made) Auto aperture size recognition, Transmittance, 0.66 in or 0.98 in (Φ 17 mm or Φ 25 mm) |
Transmittance Sample Size | No limit on sample width and height, thickness ≤ 1.9 in (50 mm) |
Repeatability | XLAV Spectrum Reflectance or Transmittance, standard deviation within 0.1%, XLAV Chromaticity value Standard deviation within ΔE x ab 0.015 x When a white calibration plate is measured 30 x at 5-sec intervals after white calibration |
Inter-Instrument Agreement | XLAV ΔE x ab 0.15 (BCRA Series II, Average measurement of 12 tiles, at 73.4 ℉ (23 ℃) |
Illuminants | A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, U30, DLF, NBF, TL83, TL84 |
Display | Reflectance and Transmittance graph or value, color value, color difference values, pass or fail, color simulation, color assessment, haze, liquid chromaticity values, color tendency |
Viewing Angles | 2° and 10° |
Color Spaces | L x a x b, L x C x h, Hunter Lab, Yxy, XYZ |
Other Indices | WI (ASTM E313-00, ASTM E313-73, CIE or ISO, AATCC, Hunter, Taube Berger, Stensby) YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Tint (ASTM E313-00, CIE, Ganz), Metamerism index Milm, stain fastness, color fastness, ISO brightness, R457, A density, T density, E density, M Density, APHA or Pt-Co or Hazen, Gardner, Say bolt, ASTM color, Haze, Total Transmittance, Opacity, Color Strength |
Color Difference | ΔE x ab, ΔE x CH, ΔE x uv, ΔE x cmc, ΔE x 94, ΔE x 00, ΔE x ab (hunter), 555 shade sort |
Storage Memory | 8 GB |
Power | 12 V or 2.5 A |
Interface | USB and RS-232 |
Operating Temperature | 40 ℉ to 104 ℉ (5 ℃ to 40 ℃) |
Operating humidity | 80% RH, 95 ℉ (at 35 ℃) no condensation |
Storage Temperature | -4 ℉ to 113 ℉ (-20 ℃ to 45 ℃) |
Storage humidity | 80% RH, 95 ℉ (at 35 ℃) no condensation |
Screen Size | 7 in (17.7 cm) Touch Screen |
Instrument Size | 16.9 in x 9.4 in x 10.2 in (430 mm x 240 mm x 260 mm) |
Weight | 23.8 lb (10.8 kg) |