Description
Overview
GAOTek optical fiber ranger live test adopts a 3.5 in (8.8 cm) high-definition touch screen, supports multi-touch and smooth operation. Internal integration of OTDR, event map, optical power, red light, flashlight and other functions in one, to meet various test needs in different occasions. Among them, the OTDR function adopts 1550 nm wavelength and built-in high-efficiency wavelength isolator. It can perform optical tests on 1490 nm and 1577 nm links. It supports up to about +10 dBm with optical test capability, and the maximum measurement range is 49.7 mi (80 km). This is used to measure the length, loss, connection quality and other parameters of the optical fiber. It can easily test the breakpoint, bend, and loss point of the optical fiber link. It is suitable for line maintenance and emergency repair testing by installation and maintenance personnel.
Features
- 2 ft (2.5 m) event area, easy to test 16.4 ft (5 m) jumper
- Intelligent Link Analysis (Event Map)
- Integrated VFL or OPM or LS, rich in functions
- Lightweight and easy to carry
- Support live test
- Maximum range 49.7 mi (80 km)
- Full touch screen operation, friendly human-computer interaction
- High-performance processor, smooth control
Technical Specifications
Wavelength | 1550 nm ±20 nm |
Dynamic Range | 20 dB |
Event Blind Zone | 8.2 ft (2.5 m) |
ATT Blind Zone | 32.8 ft (10 m) |
Test Range | 0.06 mi, 0.18 mi, 0.31 mi, 0.77 mi, 1.5 mi, 3.1 mi, 6.2 mi, 12.4 mi, 24.8 mi, 49.7 mi (100 m or 300 m or 500 m or 1.25 km or 2.5 km or 5 km or 10 km or 20 km or 40 km or 80 km) |
Pulse Width | 5 ns or 10 ns or 20 ns or 30 ns or 50 ns or 80 ns or 100 ns or 200 ns or 300 ns or 500 ns or 800 ns or 1 µs or 2 µs or 3 µs or 5 µs or 8 µs or 10 µs or 20 µs |
Ranging Accuracy | (3.2 ft (1m) + Sample interval + 0.005 % × Test distance) |
Linearity | ±0.05 dB or dB |
Max Sample Points | ≥ 20000 |
Max Sample Resolution | ≤ 1.18 in (0.03 m) |
Loss Resolution | 0.01 dB |
Loss Threshold | 0.20 dB |
Range Resolution | 0.39 in (0.01 m) |
Refractive Index | 1.00000 to 2.00000 |
Reflection Accuracy | +3 dB |
File Format | SOR Standard File Format |
Loss Analysis | 4-point method or 5-point method |
Laser Safety Level | Class II |
Connector | SC or PC |
Wave range | 800 nm to 1700 nm |
Test Range | -70 dBm to +6 dBm (optional) or -50 dBm to +26 dBm (standard) |
Resolution | 0.01 dB |
Uncertainty | ±5 % |
Frequency identification | CW or 270 Hz or 330 Hz or 1 kHz or 2 kHz |
Wavelength | 650 nm, ±20 nm |
Connector type | Universal FC or SC or ST |
Power supply | AC or DC adapter input 100 V to 240 V, 50 Hz or 60 Hz, Output 5 V, 2 A, lithium battery 3.7 V, 2200 mAh |
Battery working | stand by > 6 hrs, continuous testing > 4 hrs |
Data storage | internal > 2000 curves |
Data interface | Type-C, USB |
Working temperature | 14 ℉ to 122 ℉ ( -10 ℃ to 50 ℃) |
Storage Temperature | -40 ℉ to 158 ℉ (-40 ℃ to 70 ℃) |
Relative Humidity | 0 % to 95 % non-condensing |
Display | full touch 3.5 in (8.8 cm), 320 x 480 color LCD screen |
Size | 4.9 in x 3.1 in x 1.4 in (126 mm x 80 mm x 37 mm) |
Weight | <=0.44 lb (<=200 g) |