Description
Overview
This device has a working temperature of 32 ℉ to 131 ℉ (0 ℃ to 55 ℃), humidity of 10 to 80% RH, and consumes < 2.5 W of power at a time.
Features
- Light Handy and Easy to use
- Wide power supply range, AC85 to 400 V
- There are 2, 4, 6, 8, 10, 12, 24 zones for customers to select.
- Thermocouple input protection, prevent module damaged by mis-connection
- Thermocouple & heater inverse protection, prevent thermocouple damaged by mis-connection
- Soft-start mode, avoid the humidity make the heater burn out
- Compatible with YUDO, Athena, DME, PCS, INCOE, etc.
- Alarm when the followings occurred:
- Ultra-high or ultra-low Temperature
- Thermocouple break, short or inverse
- Thermocouple is out of its position
- Heater break, short or overload
- Output device is damaged
- Over voltage of power supply
- Protection activated in the following situations:
- Over voltage self-protected, max. AC 500 V
- Thermocouple input protection, prevent module damaged by misconnection
- Thermocouple & heater inverse protection, prevent thermocouple damaged by misconnection
- Soft-start mode, avoid the moisture make the heater burn out
- Heater dehumidified time can be extended
Technical Specifications
Certification | ISO9001, CE |
Power Supply | 1-phase 3-wire, 240Vac, 50 or 60Hz 3-phase 4-wire, 240Vac, 50 or 60Hz 3-phase 5-wire, 380Vac, 50 or 60Hz |
Sensor Type | Thermocouple J or K |
Output Type | Zero Cross or Phase Angle |
Connector Type | Customized |
Wiring Mode | Customized |
Mainframe | Black or Orange |
Control Module | HRTC-A or HRTC-B or HRTC-C or HRTC-G |
Module Quantity | 6 |
Control Mode | Auto-PID or Manual |
Control Accuracy | ±0.1% FS |
Load Capacity | 15 A, 50 W to 1650 W (110 V) 100 W to 3600 W (220 V) |
Consumed Power | < 2.5 W |
Working Humidity | 10 to 80% RH (No condensing) |
Temperature Control | 32 ℉ to 842 ℉ (0 ℃ to 450 ℃) |
Working Temperature | 32 ℉ to 131 ℉ (0 ℃ to 55 ℃) |
Storage Temperature | -4 ℉ to 158 ℉ (-20 ℃ to 70 ℃) |
Electromagnetic Compatibility For Sensor | IEC 61000-4-2 3A, IEC 61000-4-3 3A, IEC 61000-4-4 3A, IEC 61000-4-5 4A, IEC 61000-4-6 3A, IEC 61000-4-8 5A, IEC 61000-4-9 5A, IEC 61000-4-10 4A |
Supply Voltage For Sensor | DC 24 V ±10% |
Rated Power For Sensor | ≤1 W |
Operating Ambient | -40 ℉ to 176 ℉ (-40 to 80 ℃), ≤ 95% RH |
Nominal Size | 0.39 in (100mm) |