Description
Overview
Two-hand Control Monitoring Safety Relay can be connected in an 8-channel parallel safe input signal to a 2-channel PNP safe output. The input signal can be a passive signal or an OSSD transistor signal. The safe input signal of each channel consists of 2 independent input signals, A & B. This product will detect the consistency of two signals, the input is considered to be the correct signal only if the two signals jump together, otherwise the output will be turned off.
Features
- Up to 8 channels of safe input can be realized
- 3-digit parallel status display, site fault troubleshooting, simple and easy
- The input signal can be a passive signal or an OSSD transistor signal.
- Two safety outputs with output monitoring
Technical Specifications
Task | Detection Material Plastic Inputs |
Inputs | 1 NC + 1 NO |
Outputs | 2 channel NO + 1 channel NC |
Relay Terminals | Screw |
Contact Current | 6 A |
Input Voltage | 24 V ±15% |
DIN Rail Mounting | Standard 35 mm DIN Rail |
Package Gross Weight | 0.551 lb (0.250 kg) |