Description
Overview
GAOTek Silicon Pressure Transmitter is produced based on advanced technology, the key material, components and parts are imported from German, the finished instrument is strictly assembled and tested. It is widely used in Petro, Chemical, Metallurgy, Power, Food, Papermaking, Pharmaceutical, and mechanical industry.
Â
Features
- High accuracy
- Excellent stability
- Intelligent HART protocol or MODBUS RTU
- Solid-state element, plug-in type PCB
- Small size, lightweight, anti-vibration
- Measure range, zero points are adjustable
- Positive transfer up to 500%, Negative transfer low to 600%
- Damping adjustable
- Excellent overload protection performance
- No movable mechanical parts, easy maintenance
- Same structure in whole series, parts interchange is possible
- Diaphragm material selectable
- Explosion-proof structure, all-weather service
Technical Specifications
Measure Medium | Â Liquid, Gas and Steam |
 Measure Range |  0 KPa to 0.12 KPa to 0 MPa to40 MPa |
 Output Signal |  4 mA to 20 mA |
 Power Supply |  12 V DC to 45 V DC, default as 24 V DC |
 Indicator |  Pointer type linear indication 0 % to 100 % scale or 31/2 bit LCD digital display (0 Q/0 linear to 100 Q/0 linear) |
 Explosion Proof |  A: Exd II CT6       B: Intrinsic safety ia II CT6 |
 Measure Range And Zero Point |  External adjustable |
 Positive And Negative Transfer |  After positive or negative transfer on Zero point, the absolute value of the Max. and Min. measure range. Max. positive transfer value = 500% of Min. calibration measure rate Max. negative transfer value = 600% of Min. calibration measure rate |
 Static Pressure And Over Load Pressure |  4,10,25,32 MPa |
Humidity | Â Relative humidity 0 % to 100 % |
 Volume Absorb Value |  <0.16 cm3 |
 Damp (Step Response) |  When filling with silicone oil, continuously adjustable between 0.2 S to 1.67S |
 Starting Time | 2 S without preheat Technical data (without transfer, under standard working conditions, filling with silicone oil, SS316 diaphragm) |
 Accuracy |  0.25 % FS, 0.1 % FS or Customized |
 Dead Zone |  None (≤0.1 %) |
 Stability |  Do not beyond the absolute value of error against max. range limit |
 Temperature Range | Amplifier working temperature range: E output -20 °F to 199 °F (-29 ℃ to +93 ℃) (LT type: -13 °F to 158 °F (-25 ℃ to +70 ℃), S output -20 °F to 185 °F (-29 ℃ to +85 ℃) Measurement element filling with Silicone oil: -40 °F to 212 °F (-40 ℃ to +104 ℃) Flange-type pressure transmitter filling with high-temperature silicone oil: 59 °F to 597 °F (+15 ℃ to +315 ℃) Ordinary silicone oil: -40 °F to 302 °F (-40 ℃ to +150 ℃) |
Â