- Hybrid solar inverter pure sine wave output
- Intelligent LCD integration display
- Low frequency toroidal transformer lower loss
- Inverter Charger or Solar Inverter Charger or Built-in PWM or MPPT controller optional
- AC charge current 0 to 30 A adjustable and three working modes selectable
- Peak power more than 3 times and full-automatic and perfect protection function
- Added fault code query function, easy to monitor the operation in real time
- Supports diesel or gasoline generator, adapt any tough electricity situation
- Combine industrial and home usage, wall mounted design, convenient installation
Technical Specifications
Rated Power | 1 KW |
Peak Power(20ms) | 3 KVA |
Start Motor | 1 HP |
Battery Voltage | 12 or24 VDC |
DC Input Voltage Range | 10.5 to 15 VDC (Single battery voltage) |
AC Input Voltage Range | 85 VAC to 138 VAC or 170 VAC to 275 VAC |
AC Input Frequency Range | 45 Hz to 65 Hz |
Max AC Charging Current | 25 A or 15 A |
AC Charging Method | Three stage (constant current, constant voltage, floating charge) |
Efficiency (Battery Mode) | Greater than or equal to 85 % |
Output Voltage (Battery Mode) | 110 VAC plus or minus 2 % or 220 VAC plus or minus 2 % |
Output Frequency (Battery Mode) | 50 or 60 Hz plus or minus 1 % |
Output Wave (Battery Mode) | Pure Sine Wave |
Efficiency (AC Mode) | Greater than 99 % |
Output Voltage (AC Mode) | 110VAC plus or minus 10 %Â or 220 VAC plus or minus 10 % |
Output Frequency (AC Mode) | Tracking Automatically |
Output Waveform Distortion (Battery Mode) |
Less than or equal to 3 % (Linear load) |
No Load Loss (Battery Mode) | Less than or equal to 0.8 % rated power |
No Load Loss (AC Mode) | Less than or equal to 2 % rated power (charger does not work in AC mode) |
No Load Loss (Energy Saving Mode) | Less than or equal to 10 W |
LEAD | Charge Voltage 14 V and Float Voltage 13.8 V (12 V system and 24 V system times 2 and 48 V system times 4) |
OP-LE | Charge Voltage 14.2 V and Float Voltage: 13.8 V (12 V system and 24 V system times 2 and 48 V system times 4) |
LITHIUM | Charge Voltage 12.6 V (NMC battery 3 S) (12 V system and 24 V system times 2 and 48 V system times 4) |
Battery Undervoltage Alarm | 11 V and LITHIUM 9.5 V (NMC battery 3 S) (12 V system and 24 V system times 2 and 48 V system times 4) |
Battery Undervoltage Protection | 10.5 VÂ and LITHIUM 9 V (NMC battery 3 S) (12 V system and 24 V system times 2 and 48 V system times 4) |
Battery Overvoltage Alarm | Lead acid battery 15 V (12 V system and 24 V system times 2 and 48 V system times 4) |
Battery Overvoltage Protection | Lead acid battery 17 V (12 V system and 24 V system times 2 and 48 V system times 4) |
Battery Overvoltage Recovery Voltage | Lead acid battery 14.5 V (12 V system and 24 V system times 2 and 48 V system times 4) |
Overload Power Protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
Inverter Output Short Circuit Protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
Temperature Protection | Greater than 194 °F (90 °C) (Shut down output) |
A | Normal working condition, buzzer has no alarm sound |
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection |
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal |
Charging Current | 10 A or 20 A or 30 A or 40 A or 50 A or 60 A or 80 A or 100 A |
PV Input Voltage Range | PWM 15 V to 44 V (12 V system) and 30 V to 44 V (24 V system) and 60 V to 88 V (48 V system) MPPT 15 V to 120 V (12 V system) and 30 V to 120 V (24 V system) to 60 V to 120 V (48 V system) |
Max PV Input Voltage at 77 °F (25℃) | PWM 50 V (12 V or 24 system), 100 V (48 V system) and MPPT 150 V |
PV Array Maximum Power | 12 V system: 140 W or 280 W or 420 W or 560 W or 700 W or 840 W or 1120 W or 1400 W 24 V system: 280 W or 560 W or 840 W or 1120 W or 1400 W or 1680 W or 2240 W or 2800 W 48 V system: 560 W or 1120 W or 1680 W or 2240 W or 2800 W or 3360 W or 4480 W or 5600 W |
Standby Loss | Less than or equal to 3 W |
Maximum Conversion Efficiency | Greater than 95 % |
Working Mode | Battery First or AC First or Saving Energy Mode |
Transfer Time | Less than or equal 4 ms |
Display | LCD |
Thermal Method | Cooling fan in intelligent control |
Communication | RS 232 or RS 485 (Optional) |
Operating Temperature | Less than or equal to 55 dB |
Storage Temperature | 14 °F to 104 °F (- 10 ℃ to 40 ℃) |
Noise | 5 °F to 140 °F (- 15 ℃ to 60 ℃) |
Elevation | 1.24 mi (2000 m) (More than derating) |
Humidity | 0 % to 95 % No condensation |
Size | 19.29 in x 11.81 in x 5.12 in (49 cm x 30 cm x 13 cm) |
N.W. | 25.35 lb (11.5 kg) |