Description
Features
- Measure the inherent opening or closing time of 12-way metal fracture.
- Record and measure the closing bounce time for each fracture.
- Record and measure opening or closing speed and time-travel characteristic curve.
- Record the opening or closing current value.
- Simultaneously measure the 6-way closing resistance value and its pre-casting time.
Technical Specifications
Power Supply | 110 V or 60 Hz | |
Air Pressure | 12.5 psi to 15.4 psi (86 KPA to 106 KPA) | |
Temperature | -50 °F to 104 °F (-10 °C to 40 ℃) | |
Relative Humidity | ≦80% RH, non-condensing | |
Insulation Resistance | >2 MΩ | |
Dielectric Strength | 1.5 KV withstand voltage to chassis for 1 minute, no flashover and arcing |
|
Timing | Range:250 ms to 4000 ms, resolution: 0.1 ms Range:10000 ms to 20000 ms, resolution: 1ms and0.1 ms±1 digit, 1 ms± 1 digit |
|
Speed | Range: 20.00 m/s, resolution: 0.001 m/s and±0.01 m/s±1 digit | |
Current | Range: 20 A, Resolution: 0.01 A1% ±0.1 A | |
Output Power | DC 5 V to 270 V digital adjustable 20 A(instant) |