Description
[tabs style=”default”] [tab title=”Overview”]
Overview
GAO Tek Gloss Meter with Projecting Angle 20° 60° 85° guarantees high performance and increased precision of reflective capability measurements of the material. This device, that matches the international standard ISO2813 and first-class work requirements of Lends Degree Instrument Measure Test Regulations JJG696-2002 has impressive technical properties like a multi-angle measurement system with automatic adjustment, compatibility with an extensive PC system for the data transfer and analysis and impressive long life-span lamp-house. Besides that, this meter, which has been designed to be portable and easy to use, includes features such as backlight supported LCD digital display and USB interface. A feature like a buzzer sound when the operation is being executed, single key operation, automatic turn-off and on-screen display of battery levels have been added to improve the user experience. GAOTek Gloss Meter guarantees great experience and accurate measurements of the surface luster of materials such as ink, paint, marble, and plastic above others.
[/tab]
[tab title=”Features”]
Features
- With standard GB9754-88 GB9966.5 and international standard ISO2813
- All items of the performance meet the first-class work requirements of state JJG696-2002(Lens Degree Instrument Measure Test Regulations)
- Multi angles are available
- High precision measurements, excellent repetition performance
- Automatic adjustments, no need to be hand adjustment
- Backlight with LCD digital display
- Display the reminder of the battery accurately
- Buzzer sound when the operation is executing
- USB interface available
- PC software for data transfer. The data can be read by file
- Single key operation, easy to operate
- Battery and Main power supply are available
- Long life-span lamp-house, there is no need to change the lamp-house
- Turn off automatically
- Easy to carry, light stylish appearance
- It can save lots of data and every data can check the measured time
[/tab]
[tab title=”Specifications”]
Technical Specifications
Parameters | Unit | Parameters |
Projecting angle | Degree | 20° 60° 85° |
Measuring Time | Second | 0.1 |
Save Data | 734 | |
Measure Range | GU | 0-200 |
Spot | mm/inch | 20°: 10 x 10 / 0.393 x 0.393 60°: 9 x 15 / 0.354 x 0.591 85°: 5 x 38 / 0.197 x 1.496 |
Value error | GU | Less than +1.2 |
Environment Temperature | °C / °F | 0 – 40 / 32-104 |
Relative humidity | % | < 85 |
Power | V | 1.5 |
The Measuring Window Size | mm/ inch | 11 x 35 / 0.433 x 1.378 |
Dimension | mm/ inch | 136 x 91 x 46 / 5.343 x 3.582 x 1.811 |
Weight | Gram / pound / ounce | 380 / 0.8378 / 13.404 |
[/tab]
[tab title=”Applications”]
Applications
- Capable of performing the surface luster measure for printing ink, paint, bake lacquer, coating, and woodwork.
- The surface luster measure for construction decoration materials: marble, granite, glass chemical polishing brick, pottery brick.
- The surface luster measure for other non-metal materials, plastic, and sheet.
[/tab]
[tab title=”Additional Information”]
Additional Information
Instruction:
- Brief Introduction:
The technology parameter of GAOTek-GLS-103 is complete according to state standard GB9754-88、GB9966.5 and international standard ISO2813, all items of the performance meet the first-class work requirements of state JJG696-2002 (Lens Luster Degree Instrument Measure Test Regulations). - Applications:
- The surface luster measure for printing ink, paint, bake lacquer, coating, and woodwork
- The surface luster measure for construction decoration materials: marble; granite; glass chemical polishing brick and pottery brick
- The surface luster measure for plastic and sheet
- The surface luster measure for other non-metal materials
- Instrument Characteristics:
- Fine, light stylish appearance, easy to carry
- Completely intelligent design, single key operation, convenient to use
- Automatic adjustment, no need to be hand adjustment
- Long life-span lamp-house, no need to change
- Precise measure, excellent repetition performance
- LCD digital display, with backlight, accurately display the remainder of the battery
- There is buzz sound during operation
- Turn off automatically
- The USB interface can save 734 data
- Technology Parameter:
- Measure range: 0-200GU
- Stability: <±0.4 GU/30Min
- Value error: <±1.2GU
- Power: 1.5V
- Projecting angle: 20°60°85°
- Environment temperature: 0-40℃
- Relative humidity: ≤85%
- The Measuring window size:11×35mm
- Dimension:136*91*46(mm)
- Weight: 380g
- Display Instructions:
- GU — Luster unit
- Calibrate — Calibration
- Clear save — Clear the save data
- Change Ca — Modify the calibration value
- Set time — Modify the time
- Direction:
- The Display of the Menu:
- Modify the Calibration Value:
- Setting Time:
- Matters Required Attention:
- It should avoid strong light direct radiation, or it will affect the measurement precision.
- The standard board of the gauge should be kept clean, please do not touch the surface with fingers. If there is dirt on the surface, the measured precision will be affected. Wipe it with a lens cloth or absolute alcohol.
- When the battery is less than 20%, which needs to change the battery. Open the battery cover, replace the old battery with the new one, please pay attention to the joint line polarity.
- The battery should be changed when it runs up, otherwise, it stored for a long time may flow the liquid which causes damage to the instrument. It should be taken out and keep proper if it is not used for a long time.
- Services:
Press the “key” (on the side of the gauge) to start the gauge. The gauge display “calibrate?”, take the gauge into the calibration-case, and press the “key” to confirm adjustment operation, the gauge will distinguish the state board automatic and there is buzz sound to prompt, when “calibrate ok” display on the screen, 2 seconds later, the gauge is on “working condition”, and the screen display “ready”.
Take the gauge away from the calibration-case, and put the gauge on the measured object, appoint the measure window to the measured object, press the “key”, the gauge begin to measure, the luster value of the measured object will display on the screen while there is buzz sound.1 minute later, if there isn’t any other operation, the gauge will turn off automatically, or press the “key” until display nothing then release it, the gauge will turn off.
When the gauge is in working condition, press the key until display “SET MENU” then release it, the gauge is on menu-setting, the display is as below:
The cursor (Anti explicit state) is circling on the menu, when the cursor is on the option, press the “key”, and you can perform the option.
If you want to replace the stand board (black quartz crystal board), and you have to modify the calibration value. On the main menu, when the cursor is shown on “Change CAL”, press the “key”, the gauge is on “Modify the calibration value” and the screen show “Change CAL?”, if you need to modify the calibration value, press “key” to confirm and begin to perform the process, (if you needn’t modify, don’t to do anything, 2 seconds later, the gauge return the working condition). after you press the key, and the new calibration value in the order of 20°60°85°to set. When the new calibration value was confirmed, the setting (modify the calibration value) will be finished and the gauge will be on working condition.
On the main menu, when the cursor shows on “Set time”, press the “key”, and begin to set time, the cursor indicator is where you want to modify, when the data is changed to the predetermined value, press the “key” to confirm. And the cursor moves to the next position, if press the “key” twice, the cursor moves to the last position repeating the process and finished the setting time.
This instrument has a one-year quality guarantee, maintenance for all life. If there is any problem with this product, please contact the dealer.
[/tab][/tabs]