Description
Features
- IP 65 protection
- Against the sun and rain
- Four-digit display
- Accurate measurement
Technical specification
Application | Corrosive liquid |
Measuring Range | 32 ft (10 m) |
Process Connection | Thread, flange |
Process Temperature | -40 °F to 266 °F (-40 ℃ to 130 ℃) |
Process pressure | -0.1 MPa to 0.3 MPa |
Accuracy | ± 0.19 in (± 5 mm) |
Ingress Protection | IP 67 |
Frequency Range | 26 GHz |
Supply | 2-wire (DC 24 V) or 4-wire (DC 24 V or AC 220 V) |
Signal Output | 4 to 20 mA HART (2-wire or 4-wire) RS 485or Modbus |
Application | Solid material, strong dust, easy to crystallize, condensation occasion |
Measuring Range | 229 ft (70 m) |
Process Connection | Universal flange |
Process Temperature | -40 °F to 482 °F (-40 ℃ to 250 ℃) |
Process Pressure | -0.1 to 0.3 MPa (universal flange); -0.1 to 4.0 MPa (flat flange) |
Accuracy | 0.59 in (± 15 mm) |
Ingress Protection | IP 67 |
Frequency Range | 26 GHz |
Supply | 2-wire (DC 24 V) or 4-wire (DC 24 V or AC 220 V) |
Signal Output | 4 mA to 20 mA or RS 485 or Modbus |