Below are general answers on how to operate, maintain, and calibrate a mixed oscilloscope from the list of GAO Tek’s mixed oscilloscopes. To facilitate our customers to a selection of our products, we have further classified our mixed oscilloscopes by their features: benchtop, handheld, data logging, USB connectivity, multi-channel, rugged, wired, and wireless.
We have products in stock and can ship overnight to most places in the U.S. and Canada.
If you have any questions about our products or want to place an order, our technical experts can help you. Please fill out this form or email us.
Â
Operating a Mixed Oscilloscope:
Power On:
- Connect the GAO Tek mixed oscilloscope to a stable power source.
- Turn on the power using the designated switch on the instrument.
Probe Connection:
- Connect GAO Tek probes to the channels you want to use.
- Ensure proper connection of our ground leads.
Signal Input:
- Connect the signal to the input channels of the mixed oscilloscope.
- Ensure the signal amplitude adheres to the specified limits of GAO Tek.
Settings:
- Adjust the time and voltage scales on GAO Tek’s user interface.
- Configure trigger settings provided by us to stabilize the waveform.
Acquisition:
- Select the appropriate acquisition mode on our mixed oscilloscope (single, normal, or auto).
- Adjust the number of samples using our controls for accurate representation.
Analog and Digital Channels:
- If using digital channels on the GAO Tek’s mixed oscilloscope, configure their settings.
- Set up the display to show both our analogue and digital channels.
Measurement Tools:
- Utilize GAO Tek’s measurement tools such as cursors and automated measurements.
- Measure voltage, frequency, and other parameters with GAO Tek’s precision.
Maintaining a Mixed Oscilloscope:
Cleaning:
- Regularly clean our mixed oscilloscope screen with a soft, lint-free cloth.
- Clean our input connectors and probes to prevent signal degradation.
Calibration:
- Calibrate our mixed oscilloscope periodically to ensure accurate measurements.
- Follow GAO Tek’s guidelines for calibration procedures outlined in the user manual.
Firmware/Software Updates:
- Check for firmware or software updates from GAO Tek.
- Apply updates to our mixed oscilloscope to enhance performance and add new features.
Environment:
- Operate our mixed oscilloscope in a clean, dry environment.
- Avoid extreme temperatures and humidity to ensure longevity and reliability.
Probe Maintenance:
- Inspect and replace damaged GAO Tek probes promptly.
- Calibrate and compensate GAO Tek probes according to the user manual.
Calibrating a Mixed Oscilloscope:
Frequency Response:
- Use a calibration signal source to check our mixed oscilloscope’s frequency response.
- Adjust GAO Tek settings to match the known frequency accurately.
Amplitude Calibration:
- Calibrate voltage and amplitude settings using a precise voltage source.
- Adjust the gain and offset on the GAO Tek mixed oscilloscope to match the known values.
Probe Compensation:
- Compensate GAO Tek probes using the built-in compensation signals.
- Adjust GAO Tek probe settings to meet the mixed oscilloscope’s requirements.
Time Base Calibration:
- Use a stable time reference source to calibrate the time base of our mixed oscilloscope.
- Adjust the time scale and position on GAO Tek’s user interface to match the known time intervals.
Digital Channels:
- Calibrate our mixed oscilloscope’s digital channels by verifying threshold levels and logic states.
- Adjust settings on GAO Tek’s user interface to ensure accurate representation of digital signals.