Below are general answers on how to operate, maintain, and calibrate an ozone gas detector from the list of GAO Tek’s ozone gas detectors. To facilitate our customers to a selection of our products, we have further classified our ozone gas detectors by their features:  alarm-enabled,  electrochemical, benchtop, outdoor, handheld, data logging, high precision, multi-gas detection, wide-range, wireless, and rugged.

We have products in stock and can ship overnight to most places in the U.S. and Canada.

If you have any questions about our products or want to place an order, our technical experts can help you. Please fill out this form or email us.

 

Operating an Ozone Gas Detector:

Power On:

  • Connect the ozone gas detector to a stable power source.
  • Turn on the power switch and allow the instrument to warm up for a few minutes.

Check Sensor Function and Battery:

  • Ensure all sensors are functioning correctly. Most detectors perform an automatic self-check during startup.
  • Use the mode selector to choose the appropriate measurement mode for your component.

Understand Alarms and Display:

  • Familiarize yourself with the detector’s alarm system and display readings. Understand what each type of alarm signifies.

Use Correctly:

  • Wear or place the detector in a location where it can accurately assess the atmosphere, typically within the breathing zone (chest level).

Set Alarm Thresholds:

  • Configure alarm thresholds as appropriate for your specific environment and according to relevant safety standards or guidelines.

 

Maintaining an Ozone Gas Detector:

Clean the Terminals:

  • Regularly clean the test terminals using a soft brush or compressed air to remove any dust, dirt, or oxidation that may affect measurements.

Handle with Care:

  • Treat the ozone gas detector gently and avoid dropping it or subjecting it to physical stress.
  • Store the instrument in a clean, dry environment when not in use.

Sensor and Filter Check:

  • Check sensors and filters for blockages or debris. Replace filters as recommended by GAO Tek.

Update Firmware (if applicable):

  • If your ozone gas detector has firmware that can be updated, check for updates, and apply them as needed to enhance performance and add features.

 

Calibrating an Ozone Gas Detector:

External Calibration Standards:

  • Use external calibration standards like precision resistors, capacitors, and inductors with known values to calibrate the ozone gas detector.
  • Follow the calibration procedure outlined in the instrument’s manual.

Internal Calibration (if available):

  • Some GAO’s ozone gas detectors have internal calibration routines. Follow the manufacturer’s instructions to perform internal calibration if applicable.

Understand Calibration Frequency:

  • Refer to GAO Tek’s guidelines to determine how frequently calibration is required, which is often dependent on usage and environment.

Document Calibration:

  • Keep detailed records of calibration procedures, dates, and results. This documentation is crucial for quality control and traceability.