Description
Overview
This Handheld Multi 6 Gas Detector dimensions of 9.05 in x 8.27 in x 4.72 in (230 mm × 210 mm × 120 mm), weight of 5.51 lb, and uncertainty of ≤ ± 2 %.
Technical Specifications
Gases To Be Detected | Arbitrary combination of 1 to 6 types of gases which can be expanded to 18 or more types of gases, such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on. |
Application Scenarios | All the cases which require the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on. |
Detection Range | 0 ppm to 1 ppm, 10 ppm, 100 ppm, 1000 ppm, 5000 ppm, 50000 ppm, 100000 ppm, 200 mg/L, 100 % LEL, 20 % Vol, 50 % Vol, 100 % Vol, can be selected; and other ranges can be customized. |
Resolution | 0.01 ppm or 0.001 ppm (0 ppm to 10 ppm); 0.01 ppm (0 ppm to 100 ppm), 0.1 ppm (0 ppm to 1000 ppm), 1 ppm (0 ppm to 10000 ppm or more), 0.01 mg/l (0 mg/l to 200 mg/l), 0.1 % LEL, 0.01 % LEL 0.001 % Vol |
Detection principle | Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand. |
Allowable error | ≤ ± 2 % F.S (other or higher precision levels can be customized) |
Repeatability | ≤ ± 2 % |
Uncertainty | ≤ ± 2 % |
Recovery time | ≤ 30 seconds |
Linearity | ≤ ± 2 % |
Response time | T90 ≤ 20 seconds |
Power supply | 3.6 V DC, 10000 mA high-capacity rechargeable polymer battery |
Detection Mode | Built-in pump-suction type measurement, and flow rate at 800 ml / min. Calibration flow rate should be greater than 800 ml / min, three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass. |
Alarm Mode | It is possible to set as sound & light alarm, vibration alarm, turning off the alarm. |
Communication Interface | USB (charging and communication), optional: RS232, infrared communication, automatic recognition |
Data Storage | Standard configuration is the data storage capacity for 100, 000 entries; SD card storage and USB disk storage functions are optional configuration. |
Protection Level | IP66 |
Explosion-Proof Type | Intrinsically safe type |
Explosion-Proof Mark | Exia II CT6 |
Sample Gas Temperature | – 40 °F to 158 °F (- 40 ℃ to 70 ℃), and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 2372 °F (1300 ℃). |
Working Environment | Temperature: – 40 °F to 158 °F (- 40 ℃ to 70 ℃), humidity: ≤ 10 % RH to 95 % RH, and built-in filters can be used in high humidity or high dust environment. |
Exterior Dimensions | 9.05 in x 8.27 in x 4.72 in (230 mm × 210 mm × 120 mm) |
Weight | 5.51 lb (2.5 kg) |