GAOTek Handheld Spectrum Analyzer

GAOTek Handheld spectrum analyzer High protection portable design, sturdy and durable can be used in laboratory, more suitable for field mobile use built-in large capacity lithium battery, can work for more than 4 hrs.

Description

Description

Overview

GAOTek Handheld spectrum analyzer High protection portable design, sturdy and durable can be used in laboratory, more suitable for field mobile use built-in large capacity lithium battery, can work for more than 4 hrs. 18650 rechargeable battery. USB or LAN communication, easy for long-range control. 5.6 in highlight color display, 640 X 480 resolution, waveform display clearly.

 

Features

  • High protection portable design, sturdy and durable, can be used in laboratory
  • Built-in large capacity lithium battery, can work for more than 4 hrs
  • 6 in highlight color display, 640 x 480 resolution, waveform display clearly
  • Integration USB Host & Device, support USB flash disk memory
  • Its PC software can achieve the management and storage of testing data
  • Aerospace and Defense: Radio and Radar, interferometric analysis, site repairment
  • Wireless service provider: interferometric analysis, site repairmen
  • TV & Radio: interferometric analysis, check of channel power
  • Spectrum management agency: spectrum monitor

 

Technical Specifications

Frequency Range 9 KHz to 1.6G Hz AC Coupled 5 M to 1.6 GHz
Frequency Resolution 1 Hz
Reference Frequency 10 MHz
Frequency Readout Accuracy ± (frequency indication * frequency reference uncertainty+ 1 % x span + 20 % RBW + marker resolution + 1 Hz)
Marker Resolution (Frequency span) or (number of sweep points -1)
Resolution Bandwidth
-3 dB Bandwidth 10 Hz to 1 MHz,1 to 3 to 10 sequence
Accuracy ± 5 % RBW =10 Hz to 1 MHz nominal
Resolution Filter Shape Factor < 5:1 nominal
Carrier Offset 10 K < -92 dBc/Hz, typical -95 dBc/Hz30 K < -93 dBc/Hz, typical -96 dBc/H

100 K < -95 dBc/Hz, typical -97 dBc/Hz

1 MHz < -117 dBc/Hz, typical -119 dBc/Hz

Sweep Time
Range Span > 100 Hz 2 ms to 1000 sSpan = 0 Hz 600 ns to 200 s
Sweep Mode Continuous, single
Trigger Source Free run; video; external
Trigger slope Selectable positive or negative edge
Counter Resolution 1 Hz
Accuracy ± (marker frequency × frequency reference uncertainty + counter resolution)
Log Scale and Units 1 to 10 dB/divisions in 1, 2, 5, 10 dB steps, 10 divisions displayed
Linear Scale and Units 0 to 100 %, 10 divisions displayed
Scale Unit dBm, dBmV, dBuV, Watts, Volts
Sweep (Trace) Points 461
Number of Markers 4
Detectors Normal, positive peak, sample, negative peak, RMS
Number of Traces 4
Trace Functions Clear or write, maximum hold, minimum hold, average, check, close
Level Measurement Error ±1.5 dB (excluding input VSWR mismatch)68 °F to 86 °F (20 ℃ to 30 ℃), peak detector, preamplifier off, input signal -50 dBm to 0dBm
Setting Range -100 dBm to +30 dBm, steps of 1 dB
Reference Input Frequency 10 MHz
Reference Input Amplitude 0 dBm to 10 dBm
Trigger Voltage 5V TTL level
Connector and Output Impendence N female; (50 Ω)
Display Index 5.7 inch, 640 x 480 resolution,64 M color LCD display
Temperature Range
Working 14 °F to 122 °F (-10 ℃ to +50 ℃), 32 °F to 122 °F (battery: 0 ℃ to 50 ℃)
Storage -40 °F to 158 °F (-40 ℃ to +70 ℃), -4 °F to 122 °F (battery: -20 ℃ to 50 ℃)
Relative Humidity < 95 %
Power Input voltage range: DC: 12 V to 17 V, maximum 2.8 A input 220 VAC ±15%AC frequency range: 40 Hz to 60 Hz

Power consumption: Maximum 32 W

Size 10.23 in x 8.66 in x 2.95 in (260 mm x 220 mm x 75 mm)
Weight 6.39 lb (2.9 kg)