LCR digital bridge is designed using automatic balance bridge principal component parameter analyzer, the tests of 10 Hz to 100 kHz bandwidth, frequency adjustable e.t.c.

Weight 5.07 lbs
Dimensions 10.43 × 4.13 × 12.01 in
Choose Product Options

With a test frequency of 100Hz to 10 kHz utilizing 10 points

,

With a test frequency of 100Hz to 20kHz utilizing 12 points

,

With a test frequency of 100Hz to 100kHz utilizing 16 points

,

With a test frequency of 10Hz to 10kHz utilizing 1Hz Stepping

,

With a test frequency of 10Hz to 20kHz utilizing 1Hz Stepping

,

With a test frequency of 10Hz to 100kHz utilizing 1Hz Stepping

SKU: GAOTek-LCR-214 Category:
Description

Description

Overview

GAOTek LCR digital bridge is designed using automatic balance bridge principal component parameter analyzer, the tests of 10 Hz to 100 kHz bandwidth, frequency adjustable, 0.2% of the basic classification function provided by the accuracy of measurement and instrument for the vast majority of components and materials to provide accurate and complete the survey and analysis, is widely used in product research and development, components such as incoming inspection, product online applications.

 

Features

  • Measurement frequency up to 100 kHz
  • Test level 100 mV to 2000 mV
  • Support the measurement of DC resistance and electrolytic capacitor
  • Internal bias voltage output (1 mV to 1500 mV)
  • Automatic identification of component measurement
  • 5 in (8.89 cm) TFT display, 5 and a half bits display
  • USB, RS232 communication interface, Handle sorting
  • Data recording function (maximum and minimum values, average value)
  • Support SCPI communication protocol
  • Configure system settings: language, buzzer, screen brightness.
  • Basic accuracy 0.2%
  • Manual and automatic range
  • Be equipped with open circuit and short circuit correction.
  • Comparator has sorting and alarm function.
  • Provide a variety of test ports.

 

Technical Specifications

Digits Main parameter: 5 digits; secondary parameter: 5 digits
Measurement Parameter Main parameter: L or C or R or Z; secondary parameter: X or D or Q or θ or ESR
Measurement Range(L)  0.01 μH to 9999 H
Measurement Range(C) 0.01 pF to 99999 μF
Measurement Range(R) 0.0001 Ω to 99.99 MΩ
Basic Accuracy 0.2%
Measurement Display Speed 2 t/s (slow), 4 t/s (medium speed), 8 t/s (fast)
Internal Bias 0 mV to 1500 mV adjustable, 1 mV stepping
Correction Function Open circuit correction, short circuit correction
Screening function The screening limit can be set from -50% to +50% with fixed points of 1%, 5%, 10 % and 20%
Selection of comparator Five gear sorting, third gear qualified, one gear failed, one ancillary gear
Communication Interface Standard configuration: USB, RS232 (or 485), Handle interface; Optional: GPIB, USB Host
Others Support DCR, electrolytic capacitor measurement mode, adjustable backlight brightness, optional in English and Chinese
Power supply voltage 220 V AC ±10%, or 110 V AC ±10%, 45 Hz to 65 Hz
Working environment 32 °F to 104 °F (0 ℃ to 40 ℃), relative humidity less than 80%
Storage environment 14 °F to 122 °F (-10 ℃ to 50 ℃), relative humidity less than 80%
Dimensions (W x H x D) 10.43 in x 4.13 in x 12.01 in (265 mm x 105 mm x 305 mm)
Weight 5.07 lb (2.3 kg)

Click Here to Download Technical