Description
Features
- Visual & audible alarm
- Rechargeable battery
- With air sampling pump for gas leak detection
- Low battery warning
Technical Specifications
Detecting gas |
CO, CO2, NOX, SOX |
CO2 | |
Measurement range | 0%vol to 5%vol |
Measurement error | True value ±2% |
Respond time | ≤20 S (T90) |
Resolution | 0.01%vol |
Alarm point | can be adjusted in a whole range |
Continuous working time | >3 months (without backlight) |
CO | |
Measurement range | 0 ppm to 1000 ppm |
Measurement error | 0 ppm to 20 ppm, ±2 ppm (>20 ppm to 100 ppm, ±4 ppm >100 ppm to 500 ppm, true value ±5% (>500% ppm to 1000% ppm, true value±6% |
Respond time | ≤45 S (T90) |
Resolution | 1 ppm |
Alarm point | 24 ppm (can be adjusted in the whole range) |
NOX | |
Measurement range | 0 ppm to250 ppm |
Measurement error | ±5% FS |
Respond time | ≤45 S (T90) |
Resolution | 1ppm |
Alarm point | can be adjusted in a whole range |
SOX | |
Measurement range | 0 ppm to 20 ppm |
Measurement error | ±5% FS |
Respond time | ≤45 S (T90) |
Resolution | 1 ppm |
Alarm point | can be adjusted in a whole range |
Alarm sound intensity | 80 dB |
Alarm way | Sound, light alarm |
Alarm indicator light | Can be visible at not less than 20 m |
Sensor life | ≥2 years (CO, NOX, SOX) ≥5 years (CO2) |
Working current | 95 mA |
Continuous operating hours | ≥12 hours |
Battery item | PL123450 3.7 V/1500 mA |
Battery short circuit current | 2 A |
Charging time | 4 hours to 5 hours |
Protection level | IP54 |
Working temperature | -13 oF to 131 oF (-25 ℃ to 55 ℃), short time for -40 oF to 131 oF (-40 ℃ to 55 ℃) |
Size | 5.11 in x 2.59 in x 1.18 in (130 mm × 66 mm × 30 mm) |