GAOTek Thermal Air Mass Flow Meter

GAOTek thermal air mass flow meter has no moving parts   Low pressure loss.

GAOTek-UFDAM-111

Description

Overview

GAOTek thermal air mass flow meter has no moving parts   Low pressure loss. It can measure flow of velocity. The insert type is more suitable for large pipe diameters, measuring gas mass flow without temperature and pressure compensation.

 

Technical Specification

Description Specifications
Measuring Medium Various gases (Except the acetylene)
Pipe Size DN10 to DN4000
 Velocity  0.1 Nms. to 100 Nms.
 Accuracy  1% to 2.5%
 Working Temperature  Sensor: 104 °F to 440 °F (40 ℃ to 220 ℃) Transmitter: 68 °F to 113 °F (20 °C to 45 ℃)
 Working Pressure  Insertion Sensor: medium pressure≤ 1.6 MPaFlanged Sensor: medium pressure≤ 1.6 MPa

Special pressure please contact us

 Power Supply  Compact type: 24 V DC or 220 V AC, Power consumption ≤18 WRemote type: 220 V AC, Power consumption ≤19 W
 Response Time  1 s
 Output  (optoelectronic isolation, maximum load 500 Ω), Pulse, RS485 (optoelectronic isolation) and HART
 Alarm Output  1 to 2-line Relay, Normally Open state, 10 A, 220 V, AC or 5 A,30 V, AC
 Sensor Type  Standard Insertion, Hot-tapped Insertion and Flanged
 Construction  Compact and Remote
 Pipe Material  Carbon steel, stainless steel, plastic.
 Display  4 lines LCD Mass flow, Volume flow in standard condition, Flow totalizer, Date and Time, Working time, and Velocity.
 Protection Class  IP 65
 Sensor Housing Material  Stainless steel (316)

 