GAOTek 40 G Angled Patch Panel Modular Cassette

This 40 G Angled Patch Panel Modular Cassette Assembly provides secure transitions between MPO / MTP and LC discrete connector interfaces and is suitable for copper racking systems and low power budget, high speed networks.

GAO-FRA-103

Description

Overview

GAOTek 40 G Angled Patch Panel Modular Cassette Assembly provides secure transitions between MPO / MTP and LC discrete connector interfaces and is suitable for copper racking systems and low power budget, high speed networks. They are used to interface MPO/MTP® backbones with LC patching and active equipment connections. This pre-populated panel allows rapid deployment of high density data centre infrastructure as well as improved trouble shooting and reconfiguration during moves, addition and modifications. The MPO / MTP® Angled Panels contain factory controlled and tested MPO/ MTP-LC fan-outs to deliver optical performance and reliability.

Features

  • Low insertion loss for demanding low power budget, high speed networks
  • Shallow depth of the Angled Panel makes it suitable for copper racking systems
  • High return loss (low amounts of reflection at the interface)
  • Ease of installation and easy to use
  • Reliability and low environmental sensitivity
  • 10-GbE multimode and single mode optical networks
  • Intra-building backbone and horizontal fiber interconnections
  • Inter-building OSP entrance terminations
  • Data Center and WAN main cross-connect terminations
  • Quick deployment remote data links
  • Fiber to the Subscriber (FTTX)
  • Low reflection angle polish single mode applications.

Technical Specifications

 Characteristics Conditions Specified Values
Optical Characteristics
Mode Field Diameter (MFD) 1310 nm
1550 nm
9.2 μm ±0.4 μm
10.4 μm ±0.8 μm
Cut-off Wavelength (λcc) ≤1260 nm
Attenuation Coefficient 1310 nm
1383 nm
1550 nm
≤0.35 dB/km
≤0.34 dB/km
≤0.22 dB/km
Macro Bending Loss Ф60 mm, 100circles,
at 1550 nm
≤0.05 dB
Attenuation Non-Uniformity ≤0.05 dB
Dispersion Coefficient 1288 nm~ 1339 nm
1271 nm~ 1360 nm
1550 nm
≤3.5 ps/(nm.km)
≤5.3 ps/(nm.km)
≤18 ps/(nm.km)
Zero Dispersion Wavelength 1300 nm~ 1324 nm
Max Zero Dispersion Slope ≤0.093 ps/(nm2.km)
Group Index of Refraction

(typical value)

1310 nm
1550 nm
1.466
1.467
Geometric Characteristic
Cladding Diameter 125.0 μm ±1.0 μm
Core/Cladding Concentricity Error ≤0.8 μm
CONNECTOR TYPE SC LC LC SHORT BOOT LC ANGLE BOOT
Applicable standard IEC 61754-4
TIA 604-3
IEC 61754-20
TIA 604-10-A
IEC 61754-20
TIA 604-10-A
IEC 61754-20
TIA 604-10-A
THERMICAL/MECHANICAL PERFORMANCE
Pulling load (N) 100 100 100 100
Mating cycles 1000 1000 1000 1000
Working Temperature from -40 °F to 185 °F (-40 ℃ to +85 ℃)
HOUSING COLOR
SM PC Blue Blue Blue Blue
SM APC Green Green Green Green
MM Beige Beige Beige Beige

Additional Information

International Telecommunications Union (ITU-T) Compliance

  1. G.650 Definition and Test Methods for the Relevant Parameters of Single-Mode Fibers
  2. G.652 Characteristics of Zero-Dispersion No-Shifted Single-Mode Optical Fiber Cable
  3. G.655 Characteristics of a Non-Zero Dispersion Shifted Single-Mode Optical Fiber Cable

International Electro Technical Commission Compliance

IEEE Std 1222 TM, IEEE Standard for All-Dielectric Self-Supporting Fiber Optic Cable.

Description of Optical Fibers

Optical fibers are mainly in accordance with ITU-T G.652D standards. The optical fiber core, is made of SiO2 (Silicon dioxide) doped with GeO2 (Germanium dioxide). This core has a higher refractive index compared to the cladding. The cladding of the optical fiber is made of SiO2 with a primary coating made of an UV-curable acrylate. This make-up protects the fiber against micro-bending losses and against abrasion.

Drawing Structure

Applications

  • Copper racking systems
  • Low power budget, high speed networks
  • Data Center and WAN
  • Fiber to the Subscriber (FTTX)

Ordering Information 

Mode Type Color Simplex Configuration
SM APC Green E2APCUGREEN Flange with two holes and SC footprint
SM PC Blue E2UBLUE
MM PC Beige E2UBEIGE
SM APC Green E2APCUGREEN/FL Flangeless with SC footprint
SM PC Blue E2UBLUE/FL
MM PC Beige E2UBEIGE/FL